Measuring amplifier ISG-N124M
Highlights
- Single channel test amplifier
- Sensor adjustment via analog output 0-10 V DC
- Detection range up to 55 m (180 ft)
- Manual sensitivty setting
- Permanent sensor-control
- Relay output
- Transistor output NPN / PNP
- Test input
- 2 frequency settings
- Analog output voltage 0-10 V / 10-0 V selectable
Product Description
The measuring amplifier ISG-N124M is used for testing and adjusting sensors. It is comparable with the functional features of the ISG-N124. It is possible to connect a measuring instrument 0 – 10 V via a connector located on the front which will assist in the determination of optimal visual contact between the transmitter and receiver. Diagnostics are also included for sensor wire breakage and short-circuit.
The pin configuration of the ISG-N24M amplifier is compatible with all Pantron single channel opto sensors that use an 11-pin DIN-socket.
Technical Specifications
Number of channels | 1 |
Range (using transmitter ITL combined with receiver IRL / IRH) | 10 m / 20 m (33 ft / 66 ft) |
Range (using transmitter ITH combined with receiver IRL / IRH) | 20 m / 35 m (66 ft / 115 ft) |
Range (using transmitter ITA combined with receiver IRL / IRH) | 35 m / 55 m (115 ft / 180 ft) |
Switching frequency relay / transistor | 18 Hz / 30 Hz |
Power consumption | 5 VA |
Switching output | Transistor PNP / NPN 100 mA, 30 V DC |
Connection | 11-pin DIN-plug |
Supply voltage | 230 V AC / 115 V AC / 24 V AC / 24 V DC |
Ordering Information
Supply voltage | Order code |
230 V AC | ISG-N124M/230VAC |
115 V AC | ISG-N124M/115VAC |
24 V AC | ISG-N124M/24VAC |
24 V DC | ISG-N124M/24VDC |