ISG-N138

picture ISG-N138

Highlights

  • Single channel opto sensor
  • Detection range up to 55 m (180 ft)
  • Manual sensitivity setting
  • Permanent sensor-control
  • Relay output
  • Transistor output NPN
  • Alarm output
  • On/off delay timer
  • 4 frequency settings
  • 2 level settings
  • Light/dark switching

Product Description

The device ISG-N138 is equipped with microprocessor-based technology. It is equipped with features that normally can only be found in automatic or multiplex amplifiers. Every error caused by transmitter and receiver wiring is reported immediately by the permanent sensor-control. An included time delay offers, for example, the gating of short interruptions of a light barrier or a pulse stretching. Switch-on and switch-off delay time can be activated simultaneously. The 4-fold frequency change-over is useful to decouple nearby light barriers. Two level settings allow an adjustment to be made to compensate for distance and for different operating conditions. By the use of dark switching, it is possible to reverse the switching behavior of the output. The alarm output indicates sensor errors as well as decreased visual contact caused by contamination or misalignment. Includes a relay output for high switching loads.

Technical Specifications

Number of channels

1

Range (using transmitter ITL combined with receiver IRL / IRH)

10 m / 20 m (33 ft / 66 ft)

Range (using transmitter ITH combined with receiver IRL / IRH)

20 m / 35 m (66 ft / 115 ft)

Range (using transmitter ITA combined with receiver IRL / IRH)

35 m / 55 m (115 ft / 180 ft)

Switching frequencies

50 Hz /10 Hz

Power consumption

5 VA

Switching output

Relay 5 A, 230 V AC
Transistor NPN 100 mA, 30 V DC

Alarm output, DC-supply

PNP / NPN 100 mA, 30 V DC

Alarm output, AC-supply

NPN 100 mA, 30 V DC

Delay time

0...10 s

Connection

11-pin DIN-plug

Supply voltage

230 V AC / 115 V AC / 24 V AC / 24 V DC

Ordering Information

Supply voltage

Order code

230 V AC

ISG-N138/230VAC

115 V AC

ISG-N138/115VAC

24 V AC

ISG-N138/24VAC

24 V DC

ISG-N138/24VDC

Downloads

PDF file icon

Datasheet German

PDF file icon

Datasheet English

PDF file icon

Manual

STEP file icon

CAD Data